919426570737 919426570737


Four Channel Coagulation Analyser


Four Channel Coagulation Analyser

Product Details

Computer Interface RS 232 Serial Port , USB
Power 50 Watts / 115 – 230 Volts ± 50 / 60 Hz
Operating Position On Horizontal Flat, Rigid and Vibration Free Surface
Temperature From + 18 C to 35 C
Relative Humidity Up to 85 %
Dimensions in mm (lxbxh) 345 X 300 X 140 (Approx)
Weight 5.4 kg (Approx)
Download View

Features
Coagulation

  • Four independent programmable coagulation channels for faster throughput.
  • Display online results of all four channels simultaneously on single screen.
  • Designed to perform all routine & special tests such as PT, APTT, TT, Fibrinogen, Factor II, V, VII, VIII, IX, X, XI, XII.
  • Uniform mixing of Sample & Reagent with magnetic stirrer.
  • Automatic sensing of sample/reagent dispensing to start the measurement.
  • Multipoint Calibration curve with user entered standard dilution % in FIB and Factor Assay.


Photometer :

  • Independent channel for Photometric assays.
  • Multipoint calibration curve with maximum 7 calibrators for Photometric assays.
  • Chromogenic assays antithrombin III (AT-III), protein C (PC), protein S (PS), D-dimer.


Common :

  • Effective temperature regulation system.
  • Robust system with built in stabilizer.
  • Storage Capacity of 250 open tests with QC and more than 2500 results.
  • Independent memory for Coagulation and Photometric mode.
  • Unique circuitry for long lamp life.
  • Human machine interface : Touchpad, Keypad.
  • Quality Control with Levey Jennings and standard deviation graphs.


Technical Specifications
Coagulation

  • Measuring System: Photometric / Mechanical
  • Optical Measurement: Photodiode
  • Measuring Volume: 150 μl
  • Sample & Reagent Mixing: With Magnetic Stirrer
  • Dry Block Incubator : 24 Positions Temperature at 37 c
  • Light Source: LED
  • Analysis Mode: PT, APTT, TT, Fibrinogen, Factor Assay (Factor II, V, VII, VIII, IX, X, XI, XII)
  • Results Displayed in: Seconds, Ratio, INR, Concentration and %


Photometer :

  • Linear Measurement Range : 0.000 to 3.000 Absorbance Units (A)
  • Photometric Accuracy : ± 2% or 0.007 Whichever is Higher, From 0 to 1.5 A, ± 3% from 1.5 A to 3.0 A
  • Optical Measurement : Photodiode
  • Cuvette Volume : 500 μl
  • Filters Interference : 405, 630 nm
  • Light Source : Tungsten Halogen
  • Warm Up Time : 90 Seconds
  • Analysis Mode : Absorbance, Kinetic, End Point, Fixed Time